The service is done, the unit is cold, and then you notice. The front panel sits a few millimetres proud on one side and will not click shut. Or it closes, but there is a faint buzz or rattle every time the fan speeds up. Or one end of the panel has a visible gap you swear was not there before.
The first thought is usually that the technician broke something. Sometimes that is true. But the most common and cheapest explanation is the one that takes two minutes to check: one of the filters is not seated properly. This post goes through what to look at from the floor, what to leave alone, and when the right move is to stop and send us a photograph.
First, what is behind the panel
On a wall-mounted unit the front panel hinges upward. Behind it sit two filter frames, side by side, each a plastic frame with a fine mesh. The photograph at the top of this post shows exactly that: a unit with the panel open and the two filters sitting in their slots, one on each side of the centre divider, with the front panel lifted out of the way.
The filters are the one part you are meant to touch. Everything behind them is the technician's job. Our guide to washing the filters yourself covers cleaning them. This post is about the step people rush: putting them back.
Why a filter that is not seated stops the panel closing
The filters are not identical. In the guide above we say they are often shaped for one side only, and that a filter fitted to the wrong side sits proud and lets air bypass it. "Proud" is the word that matters here: if the frame is standing slightly out of its slot, the panel has something in its way.
Three other things cause the same symptom, and they all trace back to how the filters were handled:
- Swapped sides. The left filter in the right slot, or the right one turned the wrong way up. It looks almost correct and does not quite fit.
- A warped frame. Our washing guide says hot water warps the plastic frame and that a warped filter never seats properly again. If the filters were washed in hot water, or left to dry in direct sun, the frame can bow.
- Not fully slid in at the top. The upper edge has to be in its slot before the lower edge drops. Push the bottom first and the top stays out.
A rattle that starts only when the fan speeds up points the same way: a frame that is loose in its slot can buzz against the panel when the airflow rises. That is a likely cause, not a certain one. Rattles also come from loose screws, a loose swing vane or an outdoor unit, which is what what each aircon sound means is for. Check the filters first because it costs nothing.
The two-minute check, from the floor
- Switch the unit off at the wall isolator or the breaker, not just with the remote. A remote-off unit is still live and the swing vane can move.
- Open the panel gently. It hinges upward and holds itself open. Do not force it past its stop.
- Look at the two filters from the front. Do the top edges sit level with each other and flat against the unit? Is there a visible gap between the frame and the body on either side? One end higher than the other is the tell.
- Lift each filter out, one at a time, and look at which side it came from. Hold the two side by side. If they differ in shape, make sure each goes back where it came from.
- Look at the frame, not the mesh. Hold it against a straight edge, such as the edge of a table. A bow or a twist is a warped frame.
- Refit the top edge first, let the filter settle, then press the lower edge in until it stops. Do the other side.
- Close the panel with one hand along the length of its lower edge. It should close with an even click. If you have to lean on one end, stop.
What not to do
- Do not press the panel shut against resistance. A panel forced shut over a filter that is standing proud can damage the panel or its hinge. That would be a worse problem than the one you started with.
- Do not scrub or brush the filter to "fix" it. Our washing guide is clear that the mesh is fragile and a stiff brush opens holes you cannot see.
- Do not put the filter in hot water or the sun to flatten it. That is how frames warp in the first place.
- Do not go behind the filters. Past the filters is the coil and the blower. If the panel and filters look right and the problem remains, that is the point to stop.
If the filters are fine and it still will not close
If both filters sit flat, the frames are straight and the panel still catches, do not keep trying. Take two photographs: one with the panel open showing both filters in place, and one of the gap along the panel's edge. Note which unit it is.
Then the question is whether this appeared right after a visit. If it did, say so. We take before and after photographs on our own jobs, and the photographs settle what the unit looked like when it was handed back. Our note on what your technician should show you before they leave is worth reading for the same reason: ask to see the filters refitted before the panel closes, while the technician is still there.
If it began right after a visit, ask these three things
Do not accuse anyone. The filters are the part that gets lifted out and put back on every visit, so they are the part most likely to be refitted in a hurry, and a calm question gets a faster answer than an argument.
- "Were both filters refitted to the sides they came from?" A simple answer is "yes, left to left". A vague answer is not a no, but it tells you which question to ask next.
- "Can you send me a photograph of the unit as you left it?" If a before and after photograph was taken, the filters will be in it.
- "Is the gap there in the photograph?" If the photograph shows the panel closed flush and yours is not, something has moved since. If it shows the gap, you have both seen the same thing and can agree what to do.
Any workmanship cover is separate from this checklist. On general servicing, chemical wash and chemical overhaul ours is 90 days on workmanship. A panel that will not close after one of those visits is worth raising inside that period, with the photographs, rather than after.
What this is not
A panel that will not close is a fit problem, not a cooling problem. If the unit also blows warm, ices up, or leaks, those are different questions: aircon still not cold after servicing covers the first and dripping right after a wash or service covers the second. Do not assume a panel that will not close explains them.
If it is the filters, do you pay for a visit?
Refitting a filter is something you can do yourself, as above, so there is no reason to book anything for that. If it turns out the frame is warped, a filter that will not seat is a filter that is letting air bypass the mesh, and the honest answer is to replace the frame rather than push it in. We have not published a price for a replacement filter, so we do not give one here. Send the photographs and we will tell you what we would do.
If you would rather book a visit and have it looked at on the day: general servicing on our pricing page is $55 for 1 unit, and the visit starts with the 9-point pre-check. The price shown is the final price. What is included in aircon servicing is set out on that page.
If you would like us to look at it
Send us the two photographs and tell us which unit it is and whether the problem began right after a wash or service. WhatsApp us on 9107 2601 and we will tell you what a visit would cover before we come.